Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Card Surg ; 34(1): 50-62, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30629770

RESUMO

AIMS OF THE STUDY: The safety and efficacy of a hemostatic powder (HP) versus a control agent, absorbable gelatin sponge and thrombin (G + T), were assessed, using a validated, quantitative bleeding severity scale. METHODS: Subjects were randomized to receive HP (256 subjects) or G + T (132 subjects) for treatment of minimal, mild, or moderate bleeding at 20 investigational sites. The primary efficacy endpoint was non-inferiority of HP relative to G + T for success at achieving hemostasis within 6 minutes. Secondary endpoints in rank order included: superiority of HP relative to G + T in mean preparation time; non-inferiority of HP relative to G + T for achieving hemostasis within 3 min; superiority of HP relative to G + T for achieving hemostasis within 6 min; and superiority of HP relative to G + T for success for achieving hemostasis within 3 min. RESULTS: A total of 388 subjects were included in the primary efficacy analysis. At 6 min, hemostasis was achieved in 93.0% (238/256) of the HP group compared to 77.3% (102/132) of the G + T group (non-inferiority P < 0.0001, superiority P < 0.0001). All secondary endpoints were met. Complications were comparable between treatment groups. CONCLUSIONS: HP had superior rates of hemostasis, shorter preparation time, and a similar safety profile compared to G + T in this prospective, randomized trial using quantitative bleeding severity criteria.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Esponja de Gelatina Absorvível/farmacologia , Hemorragia Pós-Operatória/tratamento farmacológico , Trombina/farmacologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Hemostáticos/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
2.
Spine (Phila Pa 1976) ; 43(11): E664-E671, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29019803

RESUMO

STUDY DESIGN: Benchtop model with prospective surgeon video testing. OBJECTIVE: To create a surface bleeding severity scale, the SPOT GRADE (SG), for quantitative assessment of target bleeding site (TBS) blood loss. This is of particular interest for spinal surgery due to epidural bleeding and an inability to use diathermy and radiofrequency cautery close to nerve roots. SUMMARY OF BACKGROUND DATA: A novel apparatus perfusable at known flow rates and simulating different sized wounds was used to create movies to educate surgeons on specific degrees of bleeding. METHODS: Training (36) and testing (108) videos were created using a benchtop apparatus employing different bleeding severities based on the six-level SG (none, minimal, mild, moderate, severe, and extreme) and TBS sizes (1, 10, and 50 cm). Fourteen surgeons in four specialties (cardiothoracic, abdominal, spine, and orthopedic lower extremity) were trained and tested to evaluate SG characteristics including inter-rater and intrarater reliability. RESULTS: The interclass correlation coefficient was estimated to be 0.89840 (95% confidence interval [CI]: 0.85771, 1), whereas the intraclass correlation coefficient was estimated to be 0.93673 (95% CI: 0.89603, 1). In 98% of cases (95% CI: 0.9736, 0.9927), surgeons correctly identified eligible bleeds for a future clinical trial (scores = 1, 2, or 3) and in 91% of cases (95% CI: 0.8895, 0.9344), surgeons correctly identified noneligible bleeds (scores = 4 or 5). In 98.6% of cases (95% CI: 0.9777, 0.9945), physicians correctly identified true hemostasis (score = 0). Based upon these data the probability of a physician rating a bleed incorrectly as hemostasis (score = 0) is estimated to be 1.51% (95% CI: 0.0061, 0.0363). CONCLUSION: This SG is reproducible and reliable providing a basis for educating surgeons on TBS blood loss. It appears to be a new standard for evaluating wound blood loss. LEVEL OF EVIDENCE: 2.


Assuntos
Perda Sanguínea Cirúrgica , Hemorragia/diagnóstico , Ferida Cirúrgica/diagnóstico , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Cirurgiões
3.
Front Biosci (Landmark Ed) ; 14(2): 665-88, 2009 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-19273094

RESUMO

The objective of this paper is to review the properties of fluids capable to enhance oxygen transport and transfer and recent developments in this field. This paper reviews and compares two different approaches, which could be used to solve the important problem of oxygen supply in some cell and tissue cultures: 1) hemoglobin-based and 2) perfluorocarbon-based (PFC) oxygen carriers. Several types of modified hemoglobin-based oxygen carriers (HBOCs) and their preparation are reviewed, as well as advances in the field of PFC oxygen carriers. Finally, we highlight the advantages and pitfalls, when reported in the literature, associated with each technique.


Assuntos
Fluorocarbonos/metabolismo , Hemoglobinas/metabolismo , Oxigênio/sangue , Animais , Portadores de Fármacos , Humanos , Solubilidade
4.
Colloids Surf B Biointerfaces ; 65(2): 239-46, 2008 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-18538549

RESUMO

PEGylated liposomes encapsulating human hemoglobin as oxygen carriers were prepared from purified carbonylhemoglobin (HbCO) solution and a lipid mixture composed of 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC), cholesterol, 1,2-dimyristoyl-sn-glycero-3-phosphoethanolamine-N-[poly(ethylene glycol) 2000] (DMPE-PEG(2000)) and palmitic acid. Hemoglobin was extracted and purified from human blood samples. SDS-PAGE was used to assess its purity. Diameter of liposomes containing hemoglobin was controlled to approximately 200 nm using extrusion as measured by dynamic light scattering and transmission electron microscopy. Liposome size distributions were shown to remain unimodal over 14 days, even at different storage temperatures. Zeta potential measurements revealed that liposome containing hemoglobin have a net surface charge of -7.16+/-0.33 mV. Also, hemoglobin encapsulated in liposomes was able to perform several cycles of oxygen loading and unloading using oxygen (O(2)) and carbon monoxide (CO). The hemoglobin vesicle dispersion showed some toxicity as revealed by three in vitro assays in which endothelial cell (HUVECs) monolayers were exposed to these dispersions. Cytotoxicity was function of the liposome concentration in the culture medium.


Assuntos
Hemoglobinas/química , Lipossomos , Polietilenoglicóis/química , Células Cultivadas , Eletroforese em Gel de Poliacrilamida , Humanos , Concentração de Íons de Hidrogênio , Microscopia Eletrônica de Transmissão , Concentração Osmolar
5.
Artif Organs ; 31(8): 649-53, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17651121

RESUMO

The purpose of this study was to characterize emulsion preparations made of perfluorooctyl bromide (PFOB) and egg yolk phospholipid (EYP) and their cytotoxicity. Dynamic light scattering and transmission electron microscopy revealed that freshly prepared emulsions stored at different temperatures for a 24-h period have a unimodal particle size distribution with an average particle size of ca. 200 nm. The emulsion displayed a broader particle size distribution following a 14-day storage. Primary human fibroblasts exposure to PFOB/EYP emulsions permanently inhibited cell proliferation and decreased mitochondrial activity. Scanning electron microscopy pictures reveal the presence of spherical particles on the fibroblasts following exposure to the emulsions after thorough rinsing with culture media.


Assuntos
Fibroblastos/efeitos dos fármacos , Fluorocarbonos/efeitos adversos , Proliferação de Células , Células Cultivadas , Gema de Ovo , Emulsões , Humanos , Hidrocarbonetos Bromados , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...